Build with temperature control incubation system
Equipped with a grating monochromator
Comes optional PC software, to offer analysis review, validation of data
It is easy access to data via a USB interface
It measures 6 and 384 well microplates
10-inch touch screen display which is built-in powerful independent instrument control software that the user can perform board layout, parameter setting, and data analysis operations
Equipped with PMT detector that enhances the maximum sensitivity of weak luminescence signals, prevents oversaturation of high signals, effectively improves the detection range of luminescence
It comes with Fluorescence Polarization function, this function is often used to detect the interaction between small molecules and macromolecules, such as the determination of drugs and hormones, tyrosine kinase detection, receptor/ligand research, protein/polypeptide interactions, DNA/protein interactions, etc.
Time-Resolved Fluorescence (TRF) function has high sensitivity, strong specificity, good stability, and short operation flow. It is suitable for ultra-micro analysis in biology and medicine, hormone detection, viral hepatitis marker detection, target cell marker detection, and drug screening
| Light source | Xenon lamp |
| Detector | PD |
| Wavelength accuracy | 2 nm |
| Wavelength repeatability (SD) | 0.2 nm |
| Half width (FWHM) | <2.5 nm |
| Wavelength range | 200-1000 nm, 1 nm Step |
| Measure range | 0-4 OD |
| Resolution | 0.0001 OD |
| Accuracy @450 nm | 96-precision mode: ? (1.0 %+0.003 Abs) @(0.0-2.0 Abs] ?2.0 % @(2.0-3.0 Abs] |
| Repeatability @450 nm | CV < 1.0 % or SD < 0.003 fast (0.0-3.0Abs] CV < 0.5 % or SD < 0.003 accurate (0.0-3.0Abs] |
| Stray light | 0.1% @220 nm |
| Linear @450 nm | R2 ? 0.999 @[0.0 – 3.0 Abs] |
| Reading time | 96-well plate: fast <15 s |
| Luminescence detector | PMT |
| Detection limit | 15 Amol/hole; 5 Amol/hole (Photon PMT) |
| Linear dynamic range |
6 Logs |
| Crosstalk | ? 0.005 % |
| Luminescence wavelength range | 200-850 nm |
| Fluorescence reading mode | Top reading |
| Fluorescence detector | PMT |
| Fluorescence wavelength range | EX: 200-1000 nm; EM: 270-850 nm |
| Filter EX/EM | 3 Groups: EX470/EM525, EX523/EM564, EX624/EM692 (other wavelengths can be replaced) |
| Fluorescence detection limit | 1. pM |
| Fluorescence linear dynamic range | 6 Logs |
| TRF wavelength range | EX: 200-1000 nm; EM: 270-850 nm |
| TRF detection limit | 0.05 pM |
| FP Wavelength range | ?1-?2 |
| FP Detection limit | 5 mP |
| Plate | 6-384 Well |
| Shaking mode | Linear, Annular, Double annular |
| Incubation temperature | RT+4 ?C ~ 45 ?C |
| Temperature uniformity | ?0.5 ?C @37 ?C |
| Operation method | Capacitive screen touch, Mouse |
| Data capacity | 10 GB |
| Compatibility | Support PC software, Win7/Win10 64 bit |
| Network transmission | The test data report can be uploaded to the PC server through FTP |
| Port | 2 USB Type-A ports, 1 USB Type B port, 1 Ethernet port, Rs232 bus interface (connected to the injector) |
| Power supply | AC 100-240 V, 50-60 Hz |
| Dimension (W x D x H) | 440 x 420 x 315 mm |
| Net weight | 25 kg |





Reviews