Build with temperature control incubation system
Equipped with a grating monochromator
Comes optional PC software, to offer analysis review, validation of data
It is easy access to data via a USB interface
It measures 6 and 384 well microplates
Equipped with PMT detector that enhances the maximum sensitivity of weak luminescence signals, prevents oversaturation of high signals, effectively improves the detection range of luminescence
10-inch touch screen display which is built-in powerful independent instrument control software that the user can perform board layout, parameter setting, and data analysis operations
Time-Resolved Fluorescence (TRF) function has high sensitivity, strong specificity, good stability, and short operation flow. It is suitable for ultra-micro analysis in biology and medicine, hormone detection, viral hepatitis marker detection, target cell marker detection, and drug screening
| Light source | Xenon lamp |
| Detector | PD |
| Wavelength accuracy | 2 nm |
| Wavelength repeatability (SD) | 0.2 nm |
| Half width (FWHM) | <2.5 nm |
| Wavelength range | 200-1000 nm, 1 nm Step |
| Measure range | 0-4 OD |
| Resolution | 0.0001 OD |
| Accuracy @450 nm | 96-precision mode: ? (1.0 %+0.003 Abs) @(0.0-2.0 Abs] ?2.0 % @(2.0-3.0 Abs] |
| Repeatability @450 nm | CV < 1.0 % or SD < 0.003 fast (0.0-3.0Abs] CV < 0.5 % or SD < 0.003 accurate (0.0-3.0Abs] |
| Stray light | 0.1% @220 nm |
| Linear @450 nm | R2 ? 0.999 @[0.0 – 3.0 Abs] |
| Reading time | 96-well plate: fast <15 s |
| Luminescence detector | PMT |
| Detection limit | 15 Amol/hole; 5 Amol/hole (Photon PMT) |
| Linear dynamic range |
6 Logs |
| Crosstalk | ? 0.005 % |
| Luminescence wavelength range | 200-850 nm |
| Fluorescence reading mode | Top reading |
| Fluorescence detector | PMT |
| Fluorescence wavelength range | EX: 200-1000 nm; EM: 270-850 nm |
| Filter EX/EM | 3 Groups: EX470/EM525, EX523/EM564, EX624/EM692 (other wavelengths can be replaced) |
| Fluorescence detection limit | 1. pM |
| Fluorescence linear dynamic range | 6 Logs |
| TRF wavelength range | EX: 200-1000 nm; EM: 270-850 nm |
| TRF detection limit | 0.05 pM |
| Plate | 6-384 Well |
| Shaking mode | Linear, Annular, Double annular |
| Incubation temperature | RT+4 ?C ~ 45 ?C |
| Temperature uniformity | ?0.5 ?C @37 ?C |
| Operation method | Capacitive screen touch, Mouse |
| Data capacity | 10 GB |
| Compatibility | Support PC software, Win7/Win10 64 bit |
| Network transmission | The test data report can be uploaded to the PC server through FTP |
| Port | 2 USB Type-A ports, 1 USB Type B port, 1 Ethernet port, Rs232 bus interface (connected to the injector) |
| Power supply | AC 100-240 V, 50-60 Hz |
| Dimension (W x D x H) | 420 x 550 x 386 mm |
| Net weight | 33 kg |